Home  | Français | Careers | See our Ads & Articles | News Archives | About Us | :    
 
   






 
 
Home  > Products  > Davicom RTU's & Expansions > AES/EBU AUDIO DETECTOR SWITCHER
AES/EBU AUDIO DETECTOR SWITCHER

Product ordering code: DADS-01  NEW!


Davicom's AES/EBU Audio Detector Switcher (DADS-01) is designed to be used as an automatic or manual switch for AES/EBU digital audio signals. It offers all the necessary inputs and outputs to be controlled and monitored by other equipment such as the Davicom Monitoring and Control units or to be used as a standalone device.
 
The DADS-01 has sophisticated audio level detection algorithms that enable thresholds with delays to be programmed on each of its three input sources (2 digital, 1 analog).
 
 
DADSv2_REAR_W500.jpg
 
 
The DADS-01 offers the following features:
  • Normal and Low Level threshold settings on all input sources (0-99 dBFS)
  • Normal and Low Level delay on all input channels (0-99s)
  • Manual or automatic operation
  • Rear panel monitoring and control I/Os
  • USB port for connection to a PC or a Davicom DV series
  • 2 digital inputs, 1 analog input and 1 digital output
  • Test Tone -20 dBFS (1 kHz on Left Channel, 400 Hz on Right Channel)
 
 
 
 
DADS-01 SPECIFICATIONS
Digital Audio Inputs
Type
Balanced
Input Impedance 110 ohms
Connector XLR (F)
Suggested mating connector for EMC compliance
Neutrik #NC3MXCC
Analog Audio Input
Type
Balanced or single-ended
Input Impedance
10 kohms or 600 ohms (internal onboard jumpers)
Connector
Pluggable screw terminal
Supporting Sampling rates
Automatic Detection
16kHz, 32kHz, 44.1kHz, 48kHz, 88.2kHz, 96kHz, 176.4kHz and 192kHz
Audio outputs
Type
Balanced
Load impedance
110 ohms
Connector
XLR (M)
Level
3 Vp-p in 110 ohms
Cable Type STP (Shielded Twisted Pair)
Suggested mating connector for EMC compliance Neutrik #NC3FXCC
REAR Panel Outputs
Level
TTL
Connector
Pluggable screw terminal
Output functions
Source selected / Fault
Source Switching
Automatic or Manual Manual mode: selection from front panel button or rear panel connector
USB interface
Functions
Allows remote control and continuous alarm monitoring through compatible Davicom MAC units
Software remote control
Through MAC Davicom
Source selection (1, 2 or 3)
Normal / Low Level Limit
Normal / Low Level Delay
Manual / Auto Mode Selection
Manual control
Via front panel pushbuttons
Same functions as via software remote control above
Power Supply
11 - 14 Vdc, 250mA @ 12V
Dimensions
1 RU, 8.5" x 1.5" x 12" half-rack unit (tray available)
Weight
1.0 kg (2.2 lbs)
 
RoHS Compliant



 
 
 
 
 
 
   
 
Homepage  •  Contact us  •  Support  •  Sales Network  •  About us