The MiniMAC+ has been optimized for systems where the number of Inputs/Outputs is limited. It is the perfect choice for sites having only one transmitter.

 

 

INPUT/OUTPUT CONFIGURATION:

INPUTS

OUTPUTS

PORTS

Metering

(analog)

Status

(digital)

Audio

Relay /

Open Collector

Serial (RS-232)

8

16

2

8

1

 

 

CONNECTIVITY OPTIONS:

PRODUCT

suffix

MAC HARDWARE

SITE CONNECTION

-01

Internal dial-up modem

(with voice interface & DTMF control)

on RJ-11 connector

- Landline telephone

- Analog mobile telephone (with RJ-11 connector)

-02

RS-232 serial port

(no voice interface, no DTMF control)

on DB9 connector

- External serial modem (Hayes compatible)

- Satellite serial modem (Hayes compatible)

- GSM serial modem (Hayes compatible)

- RF serial link

-0103

Internal dial-up modem

(with voice interface & DTMF control)

on RJ-11 connector,

 

and IP interface

on RJ-45 connector

- Landline telephone

- Analog mobile telephone (with RJ-11 connector)

 

  OR (no simultaneous access)

 

- Ethernet connection (Internet, WAN, LAN)

-0203

RS-232 serial port

(no voice interface, no DTMF control)

on DB9 connector,

 

and IP interface

on RJ-45 connector

- External serial modem (Hayes compatible)

- Satellite serial modem (Hayes compatible)

- GSM serial modem (Hayes compatible)

 

  OR (no simultaneous access)

 

- Ethernet connection (Internet, WAN, LAN)

 

 

 REAR VIEW OF A MiniMAC-0103:

 

     

Click to enlarge

    • RS-232 port to communicate with other on-site ancillary equipment;
    • Weidmuller screw terminals for the 8 metering inputs, 2 audio inputs for monitoring via telephone, 16 status inputs and 8 relay/open collector outputs;
    • Plug for an AC/DC converter that will monitor mains;
    • RJ-11 phone jack (can be replaced by a RS-232 port) for remote control / interrogation;
    • RJ-45 Ethernet jack (optional) for remote control / interrogation;
    • XLR4 connector for power supply;
    • Ground connection lug;
    • Chassis-mounted fuse.

FRONT PANEL DISPLAY:

    • RS-232 port to connect laptop in local control mode;
    • LEDs for DC power, minor and major alarms, communications, user on line and activity;
    • Buttons for local and pause modes.

 

 

ELECTRICAL SPECIFICATIONS
System Configuration

I/O card supports 8 metering inputs, 16 status inputs, 2 audio inputs,

8 relay / open collector outputs and 1 RS-232 port.

Metering (Analog) Inputs

Resolution: 12 bits;

Unipolar;

3 ranges (automatically selected): 0 to +2.5, 0 to +10 and 0 to +40 VDC;

Impedance > 100 k§Ù.

Status (Digital) Inputs

EIA compatible;

Opto isolated;

Impedance > 22 k§Ù;

Detection levels: -12 to +0.8 VDC (low)

                           +2.4 to +12 VDC (high).

Audio Inputs

-20  to +10 dBm (300-3000 Hz);

Impedance 10 k§Ù.

Outputs (Commands)

Selectable NO/NC dry contact relays (70 VAC @ 0.4 A, 30 VDC @ 2 A)

or open collector (50 mA).

Auxiliary DC Output 5 VDC, 250 mA maximum.

Serial Port for

Local Access

9600 bps, DB9 female connector located on front panel.

Serial Port for

On-Site Ancillary Equipment

1200 to 19200 bps, DB9 male connector located on rear panel.

Serial Port for

External Modem

Available only with 02 connectivity option;

1200 to 19200 bps, DB9 male connector located on rear panel.

Internal Modem

Available only with 01 connectivity option;

RJ-11 jack located on rear panel;

Voice/Fax/Data;

56 kbps or less;

Fax up to 9600 bps;

DTMF interface.

Alarm Reporting*

Via e-mail, SMS, SNMP traps, voice interface, fax, pager (alphanumeric, voice or digital), VT-100 or optional MacNet software.

*Depends on the connectivity option of the MiniMAC.

Delay Before Action Programmable on each input, 0 to 9999 seconds.

Delay Before

Return to Normal

Programmable on each input, 0 to 9999 seconds.
Power Requirement 12 VDC, 1 A
Fuse 250 V, 3 A
Operating Temperature

32 to 122 ¡ÆF

0 to 50 ¡ÆC

 

MECHANICAL SPECIFICATIONS
Dimensions

1 RU

19 x 1 3/4 x 12 in (W x H x D)

48.3 x 4.4 x 30.5 cm

Weight

9 lbs. dry; 10 lbs. shipping

4.1 kg dry; 4.5 kg shipping

 

 

Each MiniMAC unit is shipped from the factory with the following:

  • Firmware pre-loaded into the unit
  • Installation CD including:
    • MacComm Windows-based MAC communications, control and configuration software
    • Utility programs (MAC configuration manager and MAC sensor curve fitting utility)
    • Copy of the firmware